15kV24kV 600A Izindawo zokuhlangana ze-Deadbreak Busbar
1. Isetshenziswa kumadivayisi afakwe kuma-pad, ngaphansi kwezindawo zokugcina izinto, kanye neminye imishini ukuhlukanisa, ukusungula ama-loop, ama-tap, noma ama-splices, kanye nokwenza kube lula ukushintshana kwemishini.
2. Uma ihlanganiswa nomkhiqizo olinganiswe ngokulinganayo, i-junction inikeza uxhumano oluvikelwe ngokuphelele, olucwiliswayo, noluhlukanisekayo ukuze kusebenze ukunqamula umthwalo.
3. Umzimba ubunjwe nge-EPDM esezingeni eliphezulu.
  • Imininingwane Yomkhiqizo

  • Amathegi Omkhiqizo

I-Anhuang igxile kuma-Dead break junctions, sihlinzeka ngama-Dead break junctions asezingeni eliphezulu.

Okuvamile:

Izixhumo zebhasi eziphukile ezingama-600A emgqeni wegatsha lekhebula zidlala indima yebhasi. Izici zayo zifakwe uthango oluqinile, zivaliwe ngokuphelele. Isixhumi sekhebula sohlobo lwe-T sethini lebhasi lama-600A, isixhumi sekhebula sama-T-II, ishubhu yokwandisa yama-600A kanye nesivalo esifakwe uthango sama-600A esinokwakheka komugqa wegatsha eliningi lekhebula.

Izihlanganisi ze-Deadbreak busbar ze-600A ezenziwe ngezinto zokuvikela ezisezingeni eliphezulu.

Okuqukethwe kweKithi:

●Isidumbu sebhasi

●Ishidi Lemiyalelo Yokufaka

●Isitifiketi Sekhwalithii-igeee

Ulwazi Lokwakheka Komkhiqizo:

img1

1, ISIXHUMANO SETHUPHA: Isixhumi esingu-5/8″ -11 sihlangabezana nezidingo ze-IEEE Standard386.

2 、UKUVULA KWE-EPDM!: Ukuvulela kwe-EPDM okuphekwe nge-sulfur esezingeni eliphezulu kuxutshwe futhi kwakhiwe ngaphakathi ukuze kulawulwe ngokuphelele izici zerabha ezivulelayo.

3 、ISIKHUNGO ESIQHUBEKAYO ESIPHAKATHI: Isihlangu se-EPDM esibunjiwe esinomoya ophansi sihlangabezana nezidingo ze-ANSI/IEEE Standard 592.

4 、IBHA YOKUQHUBA ITHUSI: Umugqa oqhubayo wenziwe ngethusi, Ungaqinisekisa ukuthi ugesi ubushelelezi futhi udlala kahle umphumela wokupholisa.

 

Ulwazi lwe-oda:

Incazelo Inombolo Yereferensi Ukusebenza okuqhubekayoi-voltage (kV) I-Current eqhubekayo ebizwa ngokuthi i-Normal
15kV 600A Izindawo zokuhlangana eziphukile I-AH MP2-15/600 15 600
15kV 600A Izindawo zokuhlangana eziphukile I-AH MP3-15/600 15 600
15kV 600A Izindawo zokuhlangana eziphukile I-AH MP4-15/600 15 600
Ama-24kV 600A Ama-Dead break junction I-AH MP2-24/600 24 600
Ama-24kV 600A Ama-Dead break junction I-AH MP3-24/600 24 600
Ama-24kV 600A Ama-Dead break junction I-AH MP4-24/600 24 600

 

Uphenyo

Uma unemibuzo mayelana nekhotheshini noma ukubambisana, sicela ukhululeke ukusithumelela i-imeyili ku-global@anhelec.comnoma sebenzisa ifomu lokubuza elilandelayo. Izitolo zethu zizokuthinta zingakapheli amahora angama-24. Siyabonga ngentshisekelo yakho emikhiqizweni yethu.