Ungazi yonke imikhiqizo emisha eshicilelwa lapha, futhi ubone ukukhula kwethu kanye nokusungula izinto ezintsha.
Usuku: 03-27-2025
I-Ahtg3 40 5kv 260x260x450 Epoxy Resin Wall Bushingiqhubekela phambili ekufakweni kwe-bushing kagesi odongeni lwekilasi le-A futhi idlulela ngale kokuphepha nokuqinisekiswa kwekhwalithi. Lokhu akusho nje ukuthi i-AHT isebenza ngezindinganiso eziphakeme kakhulu. Kusho ukuthi i-AHT ithatha izikhala ku-supply chain futhi iyixhumanisa nesevisi engcono kakhulu.
Kungani Ukulungiswa Kwemishini Kagesi Kubaluleke Kangaka?
Ukusebenza ezingxenyeni zikagesi, ikakhulukazi lezo eziphathelene nezinhlelo ze-voltage ephakathi noma i-voltage ephezulu kuwumsebenzi ohilela umthwalo wemfanelo omkhulu futhi odinga isilinganiso esihle sokuvuthwa. Ukuthembeka kanye nekhwalithi yezingxenye kuncike ekutheni i-AAhtg3 40 5kv 260x260x450 Epoxy Resin Wall Bushing ihlanganiswe kahle kangakanani. Lolu hlobo lwe-bushing lwenzelwe ukumelana ne-40.5kV, kanye nokufakwa kokushisa okungaphezu kwezinga elibekiwe ngenkathi kuhluka i-voltage ephezulu kakhulu.
I-Epoxy Resin Wall Bushing ingenye ingxenye yokusebenza komshini. Akunjalo neze, uma umuntu ecabanga ngemishini ezimbonini ezinobungozi obukhulu lapho izinhlelo zikagesi zidinga ukusebenza kahle, kubalulekile ukuqinisekisa ukuphepha kwayo ngenkathi kuvinjelwa izinkinga ezihlobene nokuguguleka.
Ngokuphathelene nama-bushing, avame ukufakwa ezinhlotsheni zama-transformer, ama-switchgear, ahlanganiswe nezinye izinhlelo ezisebenza ngaphansi kwamandla aphezulu okusebenza okusiza ukusekela ngokugcwele izingxenye eziphilayo zesistimu ezidinga ukuvikelwa ngenkathi kuvumela ukusebenza okuphephile. Uhlelo lwe-bushing lubamba izehlakalo zamanje nezamandla aphezulu okunikeza isivikelo ezingozini zikagesi ezenza lusebenze kahle ngenkathi luthuthukisa izingxenye zikagesi.
I-AHTG3-40.5kV Epoxy Resin Wall BushingOkuvelele
Kulabo abasebenzelana nezinhlelo zikagesi ze-medium voltage, kubalulekile ukuthi siqonde ukuthi yini eyenza i-AHTG3-40.5kV Epoxy Resin Wall Bushing ibe inketho engcono uma kuqhathaniswa nezinye izinketho ezitholakalayo.
1. Izingxenye Eziqinile Neziphakeme Zemishini Ezinikezwa yi-Epoxy Resin
I-AHTG3 yakhiwe ngama-resin epoxy anezinto ze-epoxy ezisebenza kahle kakhulu, ngenxa yokuthi anamandla okusebenza kanye nezakhiwo zikagesi ezivelele. Amandla e-resin epoxy okumelana nomswakama, ukungcola, kanye nezinye izinto eziningi zemvelo kwenze kwaba ngenye yezinto ezifunwa kakhulu ekukhiqizeni izingxenye zikagesi ezisebenza kahle kakhulu.
Inqubo ye-APG (Automated Pressure Gelation) isetshenziselwa ukubumba i-epoxy resin i-bushing, iqinisekisa ukuqina kwayo nobuqotho bayo. Ukubumba i-pressure gel kuphumela ezakhiweni ezithembekile neziqinile ezingamelana nezimo ezinzima kanye nama-voltage aphezulu.
2. Umklamo Osebenzayo Onezinhloso Eziningi kanye Nobuhle
Ubukhulu be-AHTG3-40.5kV bushing buklanywe ngaphandle ku-128mm x 100mm ubude obungu-225mm. Lokhu kuvumela ukuthi ifakwe ezinhlelweni zikagesi ezinesikhala esincane ukuze kube lula kakhulu ukuyifaka. Ubukhulu obunjalo buvumela i-wall bushing ukuthi imelane nobukhulu obukhulu bokuhlukaniswa kukagesi kanye nezidingo zokuxhumeka ngokweqile kwezinhlelo ezisebenza ngaphansi kwe-voltage elinganisiwe engu-10KV noma ngaphansi.
Akufanele kumangaze ukuthi le epoxy resin bushing izohlangana kalula nemishini yakho ngenxa yomklamo wayo osebenza kahle esikhaleni. Ilungele futhi izinhlelo zikagesi ezidinga ikhono elikhulu lokuvikela kodwa ezingafuni ama-bushing amakhulu.
3. Ukumelana Nokungcola Nomswakama
Izici ezivelele zokuvikela ukungcola kanye nomswakama ze-AHTG3-40.5kV wall bushing yizo ezenza ihluke. Ukuwohloka kanye namaphutha kagesi, noma esimweni esibi kakhulu, ukwehluleka ngokuphelele, yizici ezimbili ezilimaza kakhulu izinhlelo zikagesi.
Ukwakhiwa kwe-epoxy resin yale bushing kunikeza isivikelo esihle kakhulu esiqinile esiyisindayo enhlabathini, emswakama nakwezinye izinto ezingcolisayo ezingalimaza ukusebenza kwayo. Ivumela i-bushing ukuthi ihlanzwe nje kuphela futhi ingadingi ukulungiswa okukhethekile. Njengezinye izingxenye, i-AHTG3-40.5kV bushing akudingeki ihlolwe njalo noma igcinwe njalo, okwenza le modeli ifaneleke kakhulu konjiniyela bakagesi kanye nochwepheshe.
4. Inqubo Yokufaka Yenziwe Kulula
Inqubo yokufaka i-AHTG3-40.5kV wall bushing ilula futhi ilula. Idizayini iyindlela yokuthi i-busbar inqamule i-bushing futhi ingaxhunywa kalula ohlelweni. Kukhona ukuxhumana okungenamthungo nemishini ekhona, futhi isakhiwo sayo esincane senza kube lula ukubekwa ngaphakathi kobukhulu obubekiwe.
Ukonga isikhathi kusobala kungakhathaliseki ukuthi kuse-transformer, igiya lokushintsha noma ngisho nakweminye imishini enamandla kagesi futhi konga umzamo obekungasetshenziswa ukulungisa amaphutha ngenxa yokufakwa okungafanele.
5. Umsebenzi Ongenakulungiswa
Nge-AHTG3-40.5kV odongeni lwe-bushing, umsebenzi wokulungisa awusazwakali manje. Ukumelana kwayo okuphumelelayo nokungcola kanye nomswakama kusho ukugcinwa okuncane kanye nokuhlolwa kokulungiswa okungajwayelekile. Umsebenzi okuwukuphela kwawo ukuhlanza ukungcola okungaphezulu futhi iminyaka eminingi i-bushing izoqhubeka nokusebenza kahle.
Ngokukhetha i-AHTG3-40.5kV, uqinisekisiwe ukuthi uzothola umkhiqizo osebenza kahle ngaphandle kokunakwa njalo.
6. Ukusebenza kahle ekuhlukaniseni ukuxhumana kukagesi kuhle kakhulu
Esinye sezingcaphuno ezibaluleke kakhulu okufanele uzicabangele lapho uthenga i-wall bushing ukuhlinzeka kwayo ngokusebenza okuphezulu kokuvikela ugesi okuvikela kuma-short circuits, ukuvuza kukagesi, kanye nokuphuka. I-AHTG3-40.5kV epoxy resin wall bushing yakhiwe ngqo ngezinhloso zokuvikela ugesi futhi isebenza ukuqukatha ugesi onamandla aphezulu ngaphakathi kohlelo futhi ivimbele ukuthi ungaphumi.
Izinto ze-epoxy resin zale bushing zisebenza njengesivikelo sikagesi esihle ngoba zivimba ukuhamba kwamandla kagesi ngaphakathi kwezingxenye eziqhubayo zebushing futhi zonga amandla. Lawa mandla e-dielectric abalulekile ezinhlelweni zikagesi eziphakathi neziphezulu ezingaba yingozi kakhulu uma zibekezelelwa yinoma yiliphi izinga lokwehluleka kokufakwa kokushisa. Ukucima kukagesi, ukubhujiswa kwemishini, kanye nemililo kagesi kumane nje kungenye yemiphumela emibi engase ilandelwe.
Ngaphezu kwalokho, i-bushing yenzelwe ukumelana nama-voltage aphezulu okucindezela. Lokhu kusho ukuthi i-bushing izinzile ekushayweni kombani kanye namaphutha esistimu abangela ukwanda kwamandla kagesi ngokuzumayo. Lawa makhono enza i-bushing ithembeke ukusetshenziswa ezitshalweni, eziteshini ezincane, nasezikhungweni zokukhiqiza zezimboni ezithembele ekuqhubekeni kwamandla kagesi.
Isiphetho
Ngamafuphi, i-AHTG3-40.5kV 260x260x450 Epoxy Resin Wall Bushing ingenye into eyingqayizivele nethembekile enakekela izinhlelo zikagesi zesimanje. Le bhashi yodonga eyakhiwe nge-epoxy, enobukhulu obuncane, engangeni umswakama kanye nokungcola inikeza ukunakekelwa okulula nokungadingi ukunakekelwa kwamathuluzi ane-voltage elinganisiwe engu-10KV noma ngaphansi. Inani elikhulu lokufakwa kukagesi kwe-voltage ephakathi emhlabeni wonke kanye nophawu oluqinile lwekhwalithi.I-ANHUANGimikhiqizo iqinisa isikhundla sayo njenge-wall bushing ebalulekile yokufakwa okunjalo.
I-AHTG3-40.5kV epoxy resin wall bushing iyindlela efanelekile uma ufuna ukusebenza okwanelisayo kanye nokuthula kwengqondo okungenakuqhathaniswa. Ukuthembeka kwayo, ukunakekelwa okuncane, kanye nokuvikelwa okwanele kwenzelwe izinhlelo zakho zikagesi.