Sisiza umhlaba ukhule kusukela ngo-2004

Imikhiqizo

  • Dropout Fuse YK2 Series

    Uchungechunge lwe-Dropout Fuse YK2

    I-General Fuse Cutout uhlobo lwangaphandle lwamandla aphezulu we-transformer yokusabalalisa noma imigqa yokusabalalisa futhi isetshenziselwa ikakhulukazi ukuvikela abaguquli noma imigqa ekulweni nomthelela ophakanyiswe yisifunda esifushane, ukulayishwa ngokweqile nokushintshwa kwamanje. I-drop-out fuse cutout yakhiwe ukusekelwa kwe-insulator kanye ne-fuse carrier, oxhumana nabo be-static ababekwe ezinhlangothini ezimbili zokuxhaswa kwe-insulator kanye nokuxhumana okuhambayo okufakwe emaphethelweni amabili wesithwali sefuse. Ingaphakathi lesithwali sefuse yi-extingui ...
  • vacuum interrupter

    umshini wokuphazamisa

    Isiphazamisi se-vacuum sisebenzisa i-ceramic yamagagasi njengegobolondo lokuvikela, okokuxhumana yi-CuCr alloy, isakhiwo senkomishi yensimu kazibuthe olude, esinamandla okuphuka okuphezulu, ileveli ephezulu yokuvikela, ikhono lokucisha i-arc elinamandla, impilo ende, usayizi omncane nokugcinwa kulula, Akukho ukuqhuma ingozi, akukho ukungcola, umsindo ophansi njalonjalo. Ipharamitha enkulu yezobuchwepheshe Inani elilinganiselwe i-voltage 12kV Kukalwe imvamisa yamanje engu-630A Kukalwe imvamisa engu-50Hz Kukalwe imvamisa yamandla yesikhathi esifushane emelana namandla (1 iminithi) 42k ...
  • Dropout Fuse YK1 Series

    Uchungechunge lwe-Dropout Fuse YK1

    I-General Fuse Cutout uhlobo lwangaphandle lwamandla aphezulu we-transformer yokusabalalisa noma imigqa yokusabalalisa futhi isetshenziselwa ikakhulukazi ukuvikela abaguquli noma imigqa ekulweni nomthelela ophakanyiswe yisifunda esifushane, ukulayishwa ngokweqile nokushintshwa kwamanje. I-drop-out fuse cutout yakhiwe ukusekelwa kwe-insulator kanye ne-fuse carrier, oxhumana nabo be-static ababekwe ezinhlangothini ezimbili zokuxhaswa kwe-insulator kanye nokuxhumana okuhambayo okufakwe emaphethelweni amabili wesithwali sefuse. Ingaphakathi lesithwali sefuse yi-extinguishin ...
  • Indoor SF6 for switchgear 10KV 630A Gas Insulated Load Break Switch LBS Indoor Isolating switch

    I-SF6 yangaphakathi yokushintshela i-10KV 630A i-Gas Insulated Load Break switch switch LBS Indoor Isolating switch

    Ukusetshenziswa kwezimo zemvelo: 1. Ubude: ≤2000m; Amandla okuzamazama komhlaba: aweqi kweyisishiyagalombili. Izinga lokushisa komoya: alikho ngaphezu kuka- + 40 ℃, hhayi ngaphansi kuka -30 ℃. Isilinganiso sansuku zonke somswakama ohambisanayo esingeqile kuma-90%, isilinganiso sanyanga zonke esingeqile kuma-90%. 3. Indawo yokufaka enokudlidliza okuvame futhi okunodlame ayifanele indawo yokufaka enomphunga wamanzi, igesi, ukufakwa kwamakhemikhali okulimazayo, isifutho sikasawoti, uthuli nokungcola, izingozi zomlilo nokuqhuma okusobala ukuthi kuthinta i-perfo ...
  • Incoming operating mechanism for gas insulated switchgear

    Indlela yokusebenza engenayo yegesi eshintshiwe eshintshiwe

    Izesekeli ze-SF6 Insured switchgear: Manual / Motor: A, hard interlock / B, soft interlock Technical Parameters: Content Unit Parameter switch Contact Contact standard standard N 190-210 Open tri-phase dissimilar ms ≤2 Close tri-phase dissimilar ms ≤2 Opening average isivinini m / s 3-6 Isivinini sesilinganiso sokuvala m / s 4-6 Isigaba sesithathu sokugoqa okujwayelekile m / s ≤2 I-engeli yokukhipha izigaba ezintathu ° 88 ° Impilo yemishini Izikhathi 10000 Amandla wokusebenza N -110 Ukudweba:
  • outgoing mechanism

    indlela ephumayo

    Izesekeli ze-SF6 Insured switchgear: Imanuwali / Imoto: A, ukuhlangana kanzima / B, ukuthambeka okuthambile Amapharamitha Wezobuchwepheshe: Okuqukethwe Iyunithi Ipharamitha Shintsha ingcindezi yokuxhumana esezingeni eliphakeme N 80-190 Vula isigaba sesithathu esingafani ms ms Close Vala isigaba sesithathu esingafani ms ms ≤2 Isilinganiso sokuvula isivinini m / s 3-6 Isivinini sesilinganiso sokuvala m / s 4-6 Isigaba sesithathu sokugoqa okujwayelekile m / s ≤2 I-engeli yokukhipha izigaba ezintathu ° 88 ° Impilo yemishini Izikhathi 10000 Amandla wokusebenza N -110 Ukudweba:
  • 12kV 630A loadbreak switch

    12kV 630A switchbreak switch

    Amapharamitha Wezobuchwepheshe I-12KV Yunithi Yokuqukethwe Ipharamitha Ilinganiselwe I-Voltage KV 12 Kukalwe imvamisa HZ 50 Imali elinganiselwe Isikhathi 10000 I-triphase evulekile engafani ms ms ≤2 Ukuvala i-triphase engafani ms ms ≤2 Ukuvula ijubane eliphakathi nendawo 3-6 Ukuvala isivinini esimaphakathi m / s 4-6 Ukuphuka kwengcindezi yokusebenza komoya: 22KV -28 ...
  • SF6 Insulated Load Break Switch

    SF6 ngci Umthwalo Break Break

    Uhlolojikelele Iswishi yokulayisha uhlobo lweswitshi enedivayisi elula yokucisha i-arc. Isebenzisa igesi le-SF6 njengesixhobo sokuvala nokucisha i-arc. Ingasetshenziswa njengamanje wokuvala nokwephula umthwalo wamanje nokulayisha ngokweqile. Ingasetshenziswa futhi njengokuvala nokuphula umthwalo ongavali. Imigqa, ama-no-load transformers namabhange ama-capacitor, njll., Wonke ama-switch-position load switch anemisebenzi yokuvula, ukuvala nokwakha izinto elula ngesakhiwo futhi ayithengeki. Ngaphezu kwempilo ende, ukuqhuma okuqinile ...
  • 35kV Oil-immersed two-position loadbreak switch
  • Oil-immersed four-position loadbreak switch

    I-oyili egxilile yokushintshwa kwe-loadbreak switch

    I-12kV 630A egcwaliswe ngo-oyela indawo yokufaka umthwalo eyenzelwe u-oyili yenzelwe indandatho yohlobo lwendandatho yase-US-box ring change cabinet eyenzelwe ukuhlangabezana namazinga we-IEEE, IEC ne-GB wazo zonke izidingo. Ingasetshenziswa ezinhlelweni ezakhiwe phansi noma ngaphansi komhlaba. I-oyili egxilise indawo yokulayisha umthwalo wesine ekufakweni, eduze nomgogodla we-transformer inganciphisa uxhumano lwangaphakathi lwe-Cable capacitance, futhi ngaleyo ndlela inciphise kakhulu iluphu ku-resonance ye-ferromagnetic. Kokubili ukukhweza ohlangothini nokuphakama okuphezulu kuyatholakala Ngokujwayelekile ...
  • Oil-immersed two-position loadbreak switch

    U-oyela ocwiliswe esikhaleni esinezikhundla ezimbili

    Uwoyela ocwiliswe izikhundla ezimbili zokulayishwa kwe-loadbreak ikakhulukazi okusetshenziselwa ukugcina uhlobo lwe-American box change, ngenqubo yokusebenza yasentwasahlobo, kuyisinkinobho sokuxhuma esinezigaba ezintathu ukuqedela umsebenzi wokugqashula nokuvala umthwalo. Ngokushintshwa kokulayisha kwezikhundla ezimbili kungabuye kwenziwe ngohlelo lokushintsha indandatho yohlelo lokusatshalaliswa kohlobo lwendandatho, isimo sokushintsha indawo ezimbili: kuvuliwe, kuvaliwe. Isilinganiso se-10kV singasetshenziselwa amaphrojekthi wamandla omoya ekusetshenzisweni kweziguquli. Ngaphambi kokusebenzisa i-transformer idinga ukomiswa. M ...
  • XRNT backup fuse

    I-fuse yesipele ye-XRNT

    Isiphazamisi se-magne X sisetshenziswa ochungechungeni ngamadivayisi wokuvikela aphansi wamanje aphansi njenge-Bay-o-net Fuse noma iMagne X Isiphazamisi se-magne X. I-magne X interrupter esebenza kahle kakhulu ekunciphiseni isigaba samanje inciphisa imiphumela yengcindezi yamanje yamaphutha kwimishini nakuhlelo lokusabalalisa.Isilinganiso sayo esiphansi sokuphazanyiswa sihlanganiswa naleso sesiphazamisi esiphansi samanje ukugwema ukusebenza kwamanje okungathandeki okuphansi; kepha isilinganiso sayo esiphazamisa kakhulu sizosusa okuphezulu kakhulu ...